Cold Wave Shaping Instrument
Partition shaping
Multi‑probe design targets specific areas with precision — face, arms, abdomen, thighs.
Real‑time temperature control
Intelligent system maintains safe operation, epidermis always protected.
Minimally invasive fat melting
Non‑contact microwave energy, strong lipolysis & shaping without trauma.
Recovery without trace
Freezing reduces skin damage, recovery period shortened.
Three‑in‑one effect
Fat melting + skin tightening + body shaping — restore perfect posture.
double chin / jawline
Face
butterfly sleeves / underarm
Arms
abdomen / thighs / buttocks
Abdomen · Thighs · Buttocks
Product overview
The Cryo‑Microwave Shaping Instrument is a non‑invasive aesthetic device integrating low‑temperature freezing and microwave energy. Based on “precise targeting + gentle efficient” technology, it improves local fat accumulation, tightens skin, and reduces cellulite — while ensuring safety and comfort.
Core technology & working principle
Medical‑grade microwave frequency (24.50 MHz ± 50 MHz) penetrates to 3‑15 mm subcutaneous layer. Fat molecules absorb energy far more efficiently than water‑rich epidermis, causing fat cells to vibrate at high speed → natural apoptosis. Built‑in constant‑temperature protection (5 °C – 20 °C cooling) safeguards skin, no burn risk. Apoptotic fat is naturally metabolized within 1‑3 months. Simultaneously, microwave heat stimulates collagen regeneration, achieving fat reduction, skin tightening, and cellulite improvement in one session.
Technical specifications
| Product Name | Cold wave shaping instrument |
| Microwave Frequency | 24.50 MHz ± 50 MHz |
| Depth | 3 mm / 7 mm / 15 mm |
| Working Voltage | AC 110V/220V 50/60Hz |
| Probe Type | Specialized probes for face & body (action depth 3‑15 mm) |
| Cooling Temperature | 5 °C – 20 °C |
Scope of application
- ✓ Improve localized fat accumulation (face, abdomen, legs, arms, waist sides)
- ✓ Healthy individuals with adequate fat layer for body contour & skin tightening
Operating parameter settings
| Mild Fat Reduction | 15‑20 min | Arms, neck |
| Moderate weight loss | 20‑25 min | Waist sides, buttocks |
| Severe weight loss | 25‑30 min | Abdomen, thighs |
Note: start low power, adjust per tolerance. Cooling default ON, safe range auto‑maintained.
Contraindications
Absolute contraindications
- Pregnancy & lactation
- Cardiac pacemaker / metal implants
- Severe heart disease, coagulation disorders
- Skin infection or inflammation (acute acne, eczema, wounds)
- Abnormal fat metabolism (advanced fatty liver, hyperlipidemia crisis)
- Malignant tumors
- High fever or coagulation disorders
- Allergy to coupling agents
Relative contraindications
- Diabetes (blood glucose not controlled below 8 mmol/L)
- Sensitive skin / scar constitution
- Similar fat reduction treatments or local surgery within 3 months
- Cold sensitivity / extremely low heat tolerance
Treatment protocol
Post‑treatment care
Immediate (0‑24h)
- Avoid friction/pressure, no hot compress, sauna, hot spring
- Keep skin clean, avoid alcohol/acid products
- No bathing / strenuous exercise for 4‑6h
Long‑term (1‑3 months)
- Drink 1.5‑2L water daily
- Low‑fat, high‑protein diet, avoid high‑sugar/oil
- Light exercise after 1 week, strength after 2 weeks
- Sun protection to avoid pigmentation
Maintenance & warranty
Daily maintenance
Wipe probe with medical alcohol after each use; UV disinfection 30min weekly. After use, cool 10min before power off. Keep environment dry, ventilated, 5‑40°C, avoid EMI.
Regular maintenance
Every 3 months: detect microwave power & cooling system, calibrate. Replace magnetron after 2000h cumulative. Comprehensive overhaul annually, keep records.
Not covered: unauthorized repair, dismantling, modification; improper use, dropping, non‑original parts; force majeure.
Effect comparison
Frequently asked questions
What is Cryo‑Microwave Shaping?
Non‑invasive device integrating selective microwave lipolysis & dynamic cooling (5‑20°C). Microwaves target 3‑15mm subcutaneous fat, causing fat cell apoptosis while protecting epidermis. Reduces fat, tightens skin, improves cellulite.
Who is it suitable for?
Individuals with local fat accumulation or skin laxity. Face: double chin, buccal fat, jawline. Body: abdomen, waist, thighs, buttocks, arms, back fat.
When will results appear?
Immediate slight firming; 1‑2 weeks fat metabolism begins; best peak 1‑3 months. Destroyed fat cells do not regenerate, but remaining cells can enlarge with poor diet. Tightening lasts 6‑12 months.
Recovery period?
Virtually none. Resume normal activities immediately. Slight redness/swelling subsides within hours to max 1‑2 days.
Is it painful?
Non‑invasive; only slight warmth or firmness. Contact cooling maintains skin at ~5°C, eliminating discomfort and preventing burns.
Safety certifications?
Multiple international clearances: US FDA, EU CE, Taiwan TFDA, South Korea MFDS.
Side effects?
Mild temporary redness, warmth, or stinging; resolve naturally within hours to days.
Session duration?
Typically 10‑20 minutes per area, depending on size.
© Cold Wave Shaping Instrument — advanced cryo‑microwave body sculpting. All specifications subject to change without notice.





Reviews
There are no reviews yet.