Cold Wave Shaping Instrument
MYOSLIM professional system In stock

Cold Wave Shaping Instrument

$6,500.00

Cold Wave Shaping Instrument non-invasive cryo-microwave fat reduction skin tightening body contouring

Cryolipolysis Face Lifting
Ready for checkout Secure purchase path
1
Free shipping Professional support Secure checkout
Buyer guidance

Why clinics choose this system

Problems it addresses

Designed for professional laser programs such as hair reduction, pigment care, resurfacing, tattoo-focused work, or spot treatment services.

Technology advantage

Uses Cryolipolysis, Face Lifting to support precise energy delivery, repeatable treatment planning, and clear service positioning for clients.

Best business use

Suitable for clinics, medspas, and laser rooms expanding high-demand treatments with professional equipment.

Best-fit customer paths

Who this laser device is best for

Useful for clinics serving hair removal, pigment care, resurfacing, spot treatment, or laser service expansion needs.

Hair removal clients

For repeatable professional programs where speed, consistency, and treatment planning matter.

Pigment or resurfacing clients

For clinics treating spots, pigment, tattoo concerns, texture, or resurfacing-focused skin needs.

Laser treatment rooms

For businesses expanding high-demand laser services with professional equipment.

SKU
CWSI-001
Shipping
Free shipping calculated through checkout
Product intelligence

Product details, applications, and specifications

Review what the system does, what problems it addresses, key technical specifications, included functions, shipping details, and customer reviews.

Overview & applications

 

 

Cold Wave Shaping Instrument

Cryo‑Microwave synergy for precise body contouring · non‑invasive · intelligent protection

Partition shaping

Multi‑probe design targets specific areas with precision — face, arms, abdomen, thighs.

Real‑time temperature control

Intelligent system maintains safe operation, epidermis always protected.

Minimally invasive fat melting

Non‑contact microwave energy, strong lipolysis & shaping without trauma.

Recovery without trace

Freezing reduces skin damage, recovery period shortened.

Three‑in‑one effect

Fat melting + skin tightening + body shaping — restore perfect posture.

[ Face application ]
double chin / jawline

Face

[ Arms application ]
butterfly sleeves / underarm

Arms

[ Body application ]
abdomen / thighs / buttocks

Abdomen · Thighs · Buttocks

Product overview

The Cryo‑Microwave Shaping Instrument is a non‑invasive aesthetic device integrating low‑temperature freezing and microwave energy. Based on “precise targeting + gentle efficient” technology, it improves local fat accumulation, tightens skin, and reduces cellulite — while ensuring safety and comfort.

Core technology & working principle

Medical‑grade microwave frequency (24.50 MHz ± 50 MHz) penetrates to 3‑15 mm subcutaneous layer. Fat molecules absorb energy far more efficiently than water‑rich epidermis, causing fat cells to vibrate at high speed → natural apoptosis. Built‑in constant‑temperature protection (5 °C – 20 °C cooling) safeguards skin, no burn risk. Apoptotic fat is naturally metabolized within 1‑3 months. Simultaneously, microwave heat stimulates collagen regeneration, achieving fat reduction, skin tightening, and cellulite improvement in one session.

Technical specifications

Product Name Cold wave shaping instrument
Microwave Frequency 24.50 MHz ± 50 MHz
Depth 3 mm / 7 mm / 15 mm
Working Voltage AC 110V/220V 50/60Hz
Probe Type Specialized probes for face & body (action depth 3‑15 mm)
Cooling Temperature 5 °C – 20 °C

Scope of application

  • Improve localized fat accumulation (face, abdomen, legs, arms, waist sides)
  • Healthy individuals with adequate fat layer for body contour & skin tightening

Operating parameter settings

Mild Fat Reduction 15‑20 min Arms, neck
Moderate weight loss 20‑25 min Waist sides, buttocks
Severe weight loss 25‑30 min Abdomen, thighs

Note: start low power, adjust per tolerance. Cooling default ON, safe range auto‑maintained.

Contraindications

Absolute contraindications

  • Pregnancy & lactation
  • Cardiac pacemaker / metal implants
  • Severe heart disease, coagulation disorders
  • Skin infection or inflammation (acute acne, eczema, wounds)
  • Abnormal fat metabolism (advanced fatty liver, hyperlipidemia crisis)
  • Malignant tumors
  • High fever or coagulation disorders
  • Allergy to coupling agents

Relative contraindications

  • Diabetes (blood glucose not controlled below 8 mmol/L)
  • Sensitive skin / scar constitution
  • Similar fat reduction treatments or local surgery within 3 months
  • Cold sensitivity / extremely low heat tolerance

Treatment protocol

1. PreparationCheck device, probe, power cord. Connect power, self‑test (30s). Select mode (Fat Management/Skin Tightening), set power 20‑40W (first time), time 10‑20min per area.
2. ApplicationClean skin, apply coupling agent. Attach probe closely, start treatment, keep probe moving to avoid local overheating.
3. Intra‑opMonitor skin; if stinging/redness occurs, stop immediately.
4. Post‑opTurn off device, clean area with warm water. Mild redness/swelling/numbness normal (subsides 1‑2 weeks). Fill record, next session in 2‑4 weeks.

Post‑treatment care

Immediate (0‑24h)

  • Avoid friction/pressure, no hot compress, sauna, hot spring
  • Keep skin clean, avoid alcohol/acid products
  • No bathing / strenuous exercise for 4‑6h

Long‑term (1‑3 months)

  • Drink 1.5‑2L water daily
  • Low‑fat, high‑protein diet, avoid high‑sugar/oil
  • Light exercise after 1 week, strength after 2 weeks
  • Sun protection to avoid pigmentation

Maintenance & warranty

Daily maintenance

Wipe probe with medical alcohol after each use; UV disinfection 30min weekly. After use, cool 10min before power off. Keep environment dry, ventilated, 5‑40°C, avoid EMI.

Regular maintenance

Every 3 months: detect microwave power & cooling system, calibrate. Replace magnetron after 2000h cumulative. Comprehensive overhaul annually, keep records.

Warranty period from shipment date. Free repair for non‑human damage within warranty.
Not covered: unauthorized repair, dismantling, modification; improper use, dropping, non‑original parts; force majeure.

Effect comparison

[ Before / After visuals – clinical studies demonstrate significant fat reduction & skin tightening ]

Frequently asked questions

What is Cryo‑Microwave Shaping?

Non‑invasive device integrating selective microwave lipolysis & dynamic cooling (5‑20°C). Microwaves target 3‑15mm subcutaneous fat, causing fat cell apoptosis while protecting epidermis. Reduces fat, tightens skin, improves cellulite.

Who is it suitable for?

Individuals with local fat accumulation or skin laxity. Face: double chin, buccal fat, jawline. Body: abdomen, waist, thighs, buttocks, arms, back fat.

When will results appear?

Immediate slight firming; 1‑2 weeks fat metabolism begins; best peak 1‑3 months. Destroyed fat cells do not regenerate, but remaining cells can enlarge with poor diet. Tightening lasts 6‑12 months.

Recovery period?

Virtually none. Resume normal activities immediately. Slight redness/swelling subsides within hours to max 1‑2 days.

Is it painful?

Non‑invasive; only slight warmth or firmness. Contact cooling maintains skin at ~5°C, eliminating discomfort and preventing burns.

Safety certifications?

Multiple international clearances: US FDA, EU CE, Taiwan TFDA, South Korea MFDS.

Side effects?

Mild temporary redness, warmth, or stinging; resolve naturally within hours to days.

Session duration?

Typically 10‑20 minutes per area, depending on size.


© Cold Wave Shaping Instrument — advanced cryo‑microwave body sculpting. All specifications subject to change without notice.

 

Technology & specifications
Weight 78 kg
Dimensions 56 × 56 × 118 cm
Product Name

Cold Wave Shaping Instrument

Product Type

Non-invasive aesthetic & body contouring device

Core Technology

Low-temperature freezing + Microwave energy synergy

Working Principle

Selective microwave lipolysis + Dynamic cryo-protection

Microwave Frequency

24.50 MHz ± 50 MHz

Treatment Depth

3 mm / 7 mm / 15 mm (adjustable)

Operating Voltage

AC 110V/220V 50/60Hz

Cooling Temperature

5°C ~ 20°C (real-time adjustable)

Power Range

20W ~ 40W (recommended for first treatment)

Reviews & buyer notes
Reviews

There are no reviews yet.

Be the first to review “Cold Wave Shaping Instrument”

Your email address will not be published. Required fields are marked *