Vertical Fractional CO2 Laser for Vagina and Scar
MYOSLIM professional system In stock

Vertical Fractional CO2 Laser for Vagina and Scar

$5,999.00

Vertical fractional CO2 laser for vaginal tightening, scar removal, and full skin resurfacing.

360 Roller Diode Laser Cryolipolysis Face Lifting
Ready for checkout Secure purchase path
1
Free shipping Professional support Secure checkout
Buyer guidance

Why clinics choose this system

Problems it addresses

Designed for professional laser programs such as hair reduction, pigment care, resurfacing, tattoo-focused work, or spot treatment services.

Technology advantage

Uses 360 Roller, Diode Laser, Cryolipolysis, Face Lifting to support precise energy delivery, repeatable treatment planning, and clear service positioning for clients.

Best business use

Suitable for clinics, medspas, and laser rooms expanding high-demand treatments with professional equipment.

Best-fit customer paths

Who this laser device is best for

Useful for clinics serving hair removal, pigment care, resurfacing, spot treatment, or laser service expansion needs.

Hair removal clients

For repeatable professional programs where speed, consistency, and treatment planning matter.

Pigment or resurfacing clients

For clinics treating spots, pigment, tattoo concerns, texture, or resurfacing-focused skin needs.

Laser treatment rooms

For businesses expanding high-demand laser services with professional equipment.

SKU
DGN-L001
Shipping
Free shipping calculated through checkout
Product intelligence

Product details, applications, and specifications

Review what the system does, what problems it addresses, key technical specifications, included functions, shipping details, and customer reviews.

Overview & applications

 

 

Vertical Fractional CO2 Laser
for Vagina and Scar

Fractional resurfacing · Vaginal tightening · Scar remodeling · 360° ring technology

Clinical focus
Vagina + Scar
Dual-purpose platform: gynecology mode for vaginal rejuvenation & fractional mode for scar/stretch marks. 7 scan shapes, 4 treatment heads (vulva, gynae, pulsed, fractional).
Vaginal tightening
Labia beautify
Acne scar removal
Stretch marks
Technology core
10600nm · 3D/4D
Fractional CO2 laser induces heat shock response → collagen contraction + neocollagenesis. 360° ring laser technology ensures uniform vaginal wall heating.
7-joint light arm
Touch display
Emergency stop

Treatment modes & handpieces

Vaginal dedicated heads
Vulva treatment head · Gynecological model head · Fractional head · Pulsed mode head. Specifically designed for non-ablative vaginal tightening, labia pigmentation lightening, and internal rejuvenation.
Surgical cutting head
Zoom 0.2a 10mm Handpiece + Micro F50/F100 (500µm / 1000µm spot). Used for wart & mole removal, precise cutting, and deep resurfacing.
Fractional scanning
7 scan shapes (adjustable size & density). Spot options: 120µm (deep scars/wrinkles), 300µm (large pores/texture), 1000µm (skin toning/luminosity).

Working principle

01
Thermal micro-zones
10600nm laser penetrates dermis, creates fractional columns of vaporization + thermal damage.
02
HSP & growth factors
Heat shock protein 70 transforms into growth factor β → stimulates fibroblasts → collagen & extracellular matrix synthesis.
03
Remodeling & tightening
Long-term collagen remodeling, wound healing response. Vaginal walls shrink and tighten due to 360° ring technology.

Vaginal tightening capsule theory
Concentrated thermal heating of inner vaginal layers induces collagen & elastin contraction and regeneration. Laser irradiation angle adjustable + 360° rotation capability → compact edge contraction and noticeable shrinkage of vaginal walls. Re-establishes firm “young-like” tissue with thick, long collagen fibers.
Tightness improvement 60%
Moisture level 80%
Pink labia +70% delicacy

Proven applications

Skin resurfacing
Wrinkle removal (face/eyes/joints)
Acne scar & pits
Burn / surgery / traumatic scars
Stretch marks (striae gravidarum)
Melasma & pigmentation
Sun damage recovery
Vulva rejuvenation
Vaginal tightening & moisturizing
Skin tightening & lift

Vertical floor-standing design
50*40*110 cm
Compact upright cabinet (19.6 x 15.7 x 43.3 IN). Space-saving vertical configuration. Built-in high/low voltage power supply, cooling system, emergency stop switch and key switch for maximum safety.
7-joint light guiding arm
Steady and even output · Greatly reduces energy loss · Convenient & flexible operation · Stylish appearance, excellent handling for both vaginal procedures and facial resurfacing.
Touch display panel for parameter setting (density, scan shape, spot size).

Why fractional CO2?
Most advanced fractional skin peeling system with 10600nm wavelength. Penetrates into dermis, triggers collagen remodeling without full layer ablation. Safer compared to traditional total layer peeling lasers (CO2 or Er:YAG). Minimal downtime, effective for various scars, aged skin, and vaginal atrophy. Long-term effect of collagen remodeling + improvement of photodamage.
Vaporization → Thermal damage → Healing
Collagen stimulation → Remodeling

Clinical advantages

Vaginal rejuvenation
✓ Fast tightening, lasting constriction → 60% improvement
✓ Deep anti-aging, young level → 80% improvement
✓ Moisture & secretion → 80% improvement
✓ Vulva lightening & delicate → 70% improvement
Scar & stretch marks
✓ Dense stretch marks, large area treatment
✓ Prominent scar remodeling
✓ Acne pit correction (prevents metabolic waste accumulation)
✓ Non-ablative fractional resurfacing
Skin quality boost
✓ Wrinkles around eyes & crow’s feet
✓ Striae gravidarum & deep scars
✓ Freckles, zygomaticus nevus & hyperchromic spots
✓ 3D / 4D rejuvenation

Safety & operation
Emergency stop switch
Cut off machine power supply instantly
Key switch
Control device startup & shutdown
Cooling system
Integrated high/low voltage power supply with stable thermal management
Guided beam delivery
Light guiding beam delivers laser to target area with graphic scanner


Model Vertical Fractional CO2 Laser
Wavelength 10600nm
Spot options 120µm / 300µm / 500µm / 1000µm
Modes Fractional · Pulsed · Gynae · Vulva · 3D/4D rejuvenation
Certification CE marked · Professional device class

VERTICAL FRACTIONAL CO2 SYSTEM
Vaginal tightening · Scar removal · Full skin resurfacing

 

Technology & specifications
Weight 73 kg
Dimensions 112 × 93 × 60 cm
Laser Type

Fractional CO2

Wavelength

10600 nm

Modes

Fractional / Pulsed / Gynae / Vulva / 3D / 4D

Handpieces

Vaginal head / Vulva head / Cutting head / Micro F50 / Micro F100

Spot Sizes

120µm / 300µm / 500µm / 1000µm

Scan Shapes

7 shapes adjustable

Light Arm

7-joint articulated

Applications

Vaginal tightening / Scar removal / Wrinkle removal / Skin resurfacing / Stretch marks / Vulva rejuvenation

Reviews & buyer notes
Reviews

There are no reviews yet.

Be the first to review “Vertical Fractional CO2 Laser for Vagina and Scar”

Your email address will not be published. Required fields are marked *